A plant nobody watches is a plant that fails quietly. Every Sarvo Green STP is PLC-automated as standard, and can be delivered with cloud monitoring, mobile alarms and AI-assisted optimisation — so problems reach you before they reach the pollution control board.
< 5 min
Alarm to notification, by SMS, email and push
99%+
Typical uptime on remotely monitored plants
0
Site visits needed to check plant status
10–15%
Energy reduction from adaptive cycle control
Architecture
Four layers, from probe to prediction
L1
Field Layer
Flow, DO, pH, level, MLSS and energy instruments wired to a Siemens S7-1200 or Allen-Bradley PLC with a colour HMI. Everything the plant needs to run automatically, whether or not the internet is up.
L2
Communication Layer
Modbus TCP/IP and OPC UA on site; 4G cellular or WiFi to the cloud over MQTT. Store-and-forward buffering means no data is lost during an outage.
L3
Cloud Layer
Time-series storage of every process tag, 30 days on Smart and a full year on Smart+, with REST API access and export for consultants and pollution control board submissions.
L4
Analytics Layer
Trend analytics, energy per KL benchmarking, anomaly detection and — on Smart+ — AI-based failure prediction and automatic cycle optimisation against actual load.
Choose your tier
Basic, Smart, Smart+
Basic is included in every plant. Smart adds the cloud and your phone. Smart+ adds intelligence — prediction, optimisation and fleet benchmarking.
PLC ControlSame PLC + Ethernet module
HMI Touchscreen10-inch colour
Automatic Cycle ControlFull automatic operation
Communication4G cellular or WiFi
Cloud PlatformMQTT to cloud dashboard
User InterfaceWeb dashboard + mobile app
Data LoggingCloud: 30-day trend data
Alarm ManagementLocal + SMS / email alerts
Remote MonitoringMobile app + web dashboard
Remote ControlView only
Performance AnalyticsDaily / monthly auto reports
Predictive MaintenanceNot included
Automatic Cycle OptimizationNot included
Multi-Site Fleet ViewMultiple STPs in one dashboard
SCADA IntegrationModbus TCP/IP, OPC UA
Indicative Add-On Cost+8–12% of equipment cost
Full automation & monitoring comparison
Feature
BASIC
SMART
SMART+
PLC Control
Siemens S7-1200 / Allen-Bradley
Same PLC + Ethernet module
Same + edge computing gateway
HMI Touchscreen
7-inch colour
10-inch colour
10-inch colour
Automatic Cycle Control
Full automatic operation
Full automatic operation
Full automatic + adaptive
Communication
Local only
4G cellular or WiFi
4G + WiFi + optional Ethernet
Cloud Platform
—
MQTT to cloud dashboard
MQTT + REST API + data lake
User Interface
Local HMI only
Web dashboard + mobile app
Full mobile app + web portal + API
Data Logging
30-day local buffer
Cloud: 30-day trend data
Cloud: 1-year data + export
Alarm Management
Local hooter + HMI
Local + SMS / email alerts
SMS + email + push + escalation
Remote Monitoring
Not included
Mobile app + web dashboard
Mobile app + web dashboard
Remote Control
None
View only
Full remote parameter adjustment
Performance Analytics
Not included
Daily / monthly auto reports
AI-powered trend analysis
Predictive Maintenance
Not included
Not included
AI-based failure prediction
Automatic Cycle Optimization
Not included
Not included
AI adjusts cycle to load
Multi-Site Fleet View
Not included
Multiple STPs in one dashboard
Fleet management + benchmarking
SCADA Integration
Not included
Modbus TCP/IP, OPC UA
Modbus TCP/IP, OPC UA, MQTT
Indicative Add-On Cost
Included in base price
+8–12% of equipment cost
+15–20% of equipment cost
Instrumentation package by tier
Sensor
Range / Type
BASIC
SMART
SMART+
Maintenance
Inlet Flow Meter
0–10 m³/hr electromagnetic
Optional
Included
Included
Annual calibration check
Outlet Flow Meter
0–10 m³/hr electromagnetic
—
Included
Included
Annual calibration check
Dissolved Oxygen (DO)
0–20 mg/L optical
Optional
Included
Included
Quarterly cleaning, annual cap
pH Probe
0–14 pH
Optional
Included
Included
Monthly calibration
Level Transmitters
Ultrasonic / hydrostatic
Included
Included
Included
Annual check
Energy Meter
3-phase, kWh + power factor
—
Included
Included
None
MLSS / Turbidity
0–20,000 mg/L
—
Optional
Included
Monthly cleaning
Blower Vibration / Run Hours
Condition monitoring
Run hours only
Run hours + current
Vibration + predictive
None
AMC & lifecycle service tiers
Feature
BASIC
COMPREHENSIVE
TOTAL CARE
Visits per Year
4 (quarterly)
12 (monthly)
24 (bi-weekly) + on-call
Scope
Inspection + reporting
Inspection + minor repairs + consumables
All maintenance + repairs + spares
Consumables Included
No
Lubricants, filters, media
All consumables
Spare Parts
Customer buys
Minor spares included
All spares (excl. major equipment)
Emergency Response
Next business day
Same business day
4-hour response (8am–8pm)
Remote Monitoring
No
Monthly data review
Continuous + alert response
Performance Reporting
Quarterly summary
Monthly detailed report
Monthly + real-time dashboard
Sludge Management
Not included
Coordination only
Fully included
Indicative Cost (% of CAPEX/yr)
2–3%
4–6%
7–10%
Project journey
From first call to signed handover
01
Site Survey & Assessment
1–2 days
Sarvo engineer assesses sewage generation, available space, inlet connection, power supply, outlet options, reuse requirements and regulatory position.
What you do
Provide access, water consumption data, building plans
02
Design & Proposal
3–5 days
Technology recommendation, model selection, site-specific GA drawing, performance guarantee, pricing and AMC options in a detailed technical proposal.
What you do
Review, ask questions, approve
03
Order & Engineering
2–4 weeks
Detailed engineering, equipment procurement, civil drawings issued, PLC program developed.
Equipment manufactured and assembled, Factory Acceptance Test, delivery to site.
What you do
Ensure site readiness per our checklist
05
Installation & Commissioning
3–5 weeks
Installation, piping, electrical, PLC programming, instrument calibration, hydrostatic and integrated system tests, biological seeding, gradual loading.
What you do
Provide power, water, operator for training
06
Performance Test & Handover
1 week + handover
Three consecutive daily samples tested at an NABL-accredited lab against the performance guarantee. O&M manual, operator training, formal handover, AMC begins.